2FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FDATA-SFT-ZA-0-1--138DATA-SFT-ZA-0-1--140826278741Electrical Installation Testers6034334Test InstrumentsTest Instruments\Electrical Power TestersA0403786-F930-428C-AC2A-4F709F7D847FAB30F1D6-EB94-4B22-A350-FAB1796F07FEA846F125-0B5F-4D2D-B941-449D1E08F4CA3D4D2B16-F97A-4315-A097-4E859B9F8252E80B1134-4706-41CF-B010-F7D3161BEB0EC27C5FE5-5BE0-40E3-BAF1-3BA79951FB283EA514C8-ED59-4C77-98C3-9DEAD42936665E8D52F5-3D5B-44FF-A44C-E4F32A771BDAA64E1752-2351-4445-9626-0E0EA68C68D16EAA9244-C0F7-49FA-A87B-4C93FAA2191618E0E425-E9C6-4A3A-96BA-206C816BAAB4D431A9AC-C809-4BE0-81B5-344FAF0C1EC375112753-81BF-4F8C-9D17-3BFC7E1DBB764EC22FF8-3AB9-4C6C-878D-971D55C01D504B663F99-25FF-4C09-977B-D34A1864A57CF8092545-2922-4256-B94F-2F2A499DE51375C68360-1F55-4E71-A8D2-F0D3F4E3B5979B92EA8B-A9F4-46BE-95E1-8BAFD3EE15FE17EC0A21-2797-4245-9A18-9AA4F70A7953877B767C-6164-4AAA-9947-325E816D7478A3D58856-519B-4498-A7D2-73BA369D0D71B3182F0A-DF1E-4C29-AD7E-9B1FE4C7686E9E3A6E8D-F776-4DE1-8894-42A730D80E8CED60AD4E-8A17-4F46-B8EC-62F3F0F0F582EBDBE570-657D-4C38-B504-87F43272AD4DD3C84EA4-1468-4E01-ADFA-EDD64626BB9E347E49A3-AB84-4AE5-8A67-467B91D279C61BCBFB13-7ABC-4529-A4B7-885A4795312E213CA5DF-AF3C-4DE8-A2EA-EA33BABAF0B3DD5C4268-63CF-4E51-8B70-59FE6494F2B14B5F1E4A-CEF8-43B4-84FB-6F84D6F5D5BC801DF7FE-41C1-4C24-A05E-56941C722C0D156E9056-DBF0-4268-93C0-A616D1E60FC03EC41774-F50E-461E-A0A7-FF9CC024D0497A359A2B-3D51-434B-AAEF-3A5E8C117DBC1000V Compact Insulation Resistance Tester1000V Compact Insulation Resistance Tester Ground MeterInsulation Resistance Tester insulation resistance, LCD (2000) with a backlitHandheld Digital Insulation Resistance Tester 6000-count True RMSInsulation Resistance Tester with Auto Range True RMS Data that Hold Freq/cap Fuse and Self TestInsulation Resistance TesterInsulation Resistance Tester 500V/1000V/1500V/2500V 0%~20% High-voltage PI DAR Tester USB PC SoftwareInsulation Resistance TestersDigital Insulation Resistance Tester, 500V/1000V/2500V/5000V, Auto Range, Display Count: 9999Insulation Resistance Tester 12kVProfessional Digital Earth Tester High Efficiency Earth Ground Insulation Resistance Measure with BlacklightEarth Resistance Tester Earth Resistance Measurement 0~4000O 0~400V 50Hz/60Hz Count 4000Resistance Soil ResistivityMultifunction 3 in 1 Electrical Tester 250~1000VGround Pile Clamp Earth Resistance TesterInsulation Resistance TestersGround Pile Clamp Earth Resistance TesterInsulation Resistance MulimeterInsulation Resistance Multimeter with Auto-range and True RMSDigital Earth TesterDigital RCD (ELCB) TesterEarth LeakageEarth LeakageMultifunction Installation Tester (Compliance Tester)Insulation Resistance TestersInsulation Resistance TestersIntelligent High Voltage 10kV Insulation Resistance Tester Digital MegohmmeterClamp Earth Resistance TesterBattery Internal Resistance Tester2.5kV Insulation Resistance TestersBattery Tester2.5kV Insulation Resistance Testers5kV Insulation Resistance Testers5kV Insulation Resistance TestersUT501AUT501BUT502AUT505AUT505BUT511UT512UT512AUT513AUT516BUT521UT522UT523AUT526UT278CUT529C (SPECIAL)UT278DUT531UT533UT572UT582 UT585UT586UT593UT501CUT502CUT515BUT273 UT677AUT512DUT3550UT512EUT513BUT513C15711061359105191927343196141262111111UT501A.jpgUT501B.jpgUT502A.jpgUT505A.jpgUT505B.jpgUT511.jpgUT512.jpgUT512A.jpgUT513A.jpgUT516B.jpgUT521.jpgUT522.jpgUT523A.jpgUT526.jpgUT278C.jpgUT529C (SPECIAL).jpgUT278D.jpgUT531.jpgUT533.jpgUT572.jpgUT582.jpgUT585.jpgUT586.jpgUT593.jpgUT501C.jpgUT502C.jpgUT515B.jpgut273plus.jpgUT677A.jpgut512d.jpgut3550.jpgut512d.jpgut513b.jpgut513b.jpg34563998598376701059654177555145323861263296817228098400281823217740877936186925871147761625428253477149201486811420760541357419073239403974.44597.76880.458820.512185.46229.558688.2516711.844403.87278.357839.5526230.3966032409.337003.64700.059126.421495.86751.6516992.418692.13248.751715817098.287462.12690131002022-03-1211:23:31:0202022-03-1910:12:25:63011A0403786-F930-428C-AC2A-4F709F7D847FUT501A.jpgUT501A.jpg(PATHUPLOAD)\__upload\UniTrend\Catalogue\images0.000.00Electrical Installation Testers2AB30F1D6-EB94-4B22-A350-FAB1796F07FEFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847F1000V Compact Insulation Resistance TesterUT501A413974.402298.8500157.000001Compact Insulation Resistance Tester 100V/250V/500V/1000V, ACV 750V, Auto Range, Low Battery Indication, Backlight, Alarm Light Display, Alarm Buzzer, High Voltage Indication, Over Load Indication, Auto Discharge, Test Voltage Vice Display, 10MO Internal Resistance Test, CAT II 1000V CAT III 600V, 2000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT II 1000V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT501A.jpgUT501A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images3456E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2A846F125-0B5F-4D2D-B941-449D1E08F4CAFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847F1000V Compact Insulation Resistance Tester Ground MeterUT501B424597.73788.1000110.0000Compact Insulation Resistance Tester 100V/250V/500V/1000V, ACV 600V, Auto Range, Low Resistance 0.01?-200?, DAR, PI, Low Battery Indication, Backlight, Alarm Light Display, Alarm Buzzer, High Voltage Indication, Over Load Indication, Auto Discharge, Test Voltage Vice Display, 10MO Internal Resistance Test, CAT II 1000V CAT III 600V, 2000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT501B.jpgUT501B.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images39980E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
23D4D2B16-F97A-4315-A097-4E859B9F8252FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Tester insulation resistance, LCD (2000) with a backlitUT502A436880.455631.5500Compact Insulation Resistance Tester 500V/1000V/2500V, DCV & ACV, Auto Range, Low Battery Indication, Backlight, Alarm Light Display, Alarm Buzzer, High Voltage Indication, Over-Load Indication, Auto Discharge,Test Voltage Vice Display, PI/DAR, CAT II 1000V CAT III 600V, 2000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT502A.jpgUT502A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images59830E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2E80B1134-4706-41CF-B010-F7D3161BEB0EFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FHandheld Digital Insulation Resistance Tester 6000-count True RMSUT505A448820.57128.85006.0000Handheld Insulation Resistance Tester, 50V/100V/250V/500V/1000V Test Voltage. 0.1M?-20G?. Short Circuit Current <2mA, Low Resistance, AC/DC Voltage 600V, Auto Range, True RMS, Step Voltage, DAR, PI, Timer, High Voltage Indication, Analogue Bar Graph, Auto Power Off, Continuity Buzzer, Data Hold, Data Storage 99, Comparison, Backlight, CAT IV 600V, 6000 Count

RANGE: AUTO
TRMS: YES
SPECIFICATION: CE/RoHS
CAT RATING: CAT IV 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT505A.jpgUT505A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images76700E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2C27C5FE5-5BE0-40E3-BAF1-3BA79951FB28FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Tester with Auto Range True RMS Data that Hold Freq/cap Fuse and Self TestUT505B4512185.48407.650013.0000Handheld Insulation Resistance Tester, 50V/100V/250V/500V/1000V Test Voltage. 0.1M?-200G?. Short Circuit Current <2mA, Low Resistance, AC/DC Voltage 600V, Leakage Current 10~2000µA, General Resistance 0.0kO~1000kO, Frequency 450Hz, Capacitance 100pF~10µF, Auto Range, True RMS, Step Voltage, DAR, PI, Timer, High Voltage Indication, Analogue Bar Graph, Auto Power Off, Continuity Buzzer, Data Hold, Data Storage 99, Comparison, Backlight, CAT IV 600V, 6000 Count

RANGE: AUTO
TRMS: YES
SPECIFICATION: CE/RoHS
CAT RATING: CAT IV 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT505B.jpgUT505B.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images105960E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
23EA514C8-ED59-4C77-98C3-9DEAD4293666FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance TesterUT511466229.554974.90005.0000Insulation Resistance Tester 100V/250V/500V/1000V, DCV 1000V, ACV 750V, Low Resistance 999.9O, Auto Range, Auto Power Off, Low Battery Indication, Data Logging 18, Comparison, Polarisation Index (PI), Dielectric Absorption (DAR), Backlight, Analogue Bar Graph, Over Range Warning, High Voltage Indication, Timer -30 Minutes, 10000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT511.jpgUT511.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images54170E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
25E8D52F5-3D5B-44FF-A44C-E4F32A771BDAFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Tester 500V/1000V/1500V/2500V 0%~20% High-voltage PI DAR Tester USB PC SoftwareUT512478688.257177.15009.0000Insulation Resistance Tester 500V/1000V/1500V/2500V, DCV 600V, ACV 600V, Auto Range, Auto Power Off, Low Battery Indication, Data Logging 18, Comparison, Polarisation Index (PI), Dielectric Absorption (DAR), USB, Backlight, Analogue Bar Graph, Over Range Warning, High Voltage Indication, Timer -15 Minutes, 10000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT512.jpgUT512.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images75550E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
26EAA9244-C0F7-49FA-A87B-4C93FAA21916FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FDigital Insulation Resistance Tester, 500V/1000V/2500V/5000V, Auto Range, Display Count: 9999UT513A4916711.810683.850010.0000Insulation Resistance Tester 500V/1000V/2500V/5000V, DCV 600V, ACV 600V, Auto Range, Secondary Display, Auto Power Off, Low Battery Indication, Data Logging 18, Comparison, Polarisation Index (PI), Dielectric Absorption (DAR), USB, Backlight, Analogue Bar Graph, Over Range Warning, High Voltage Indication, Timer -15 Minutes, Meets IEC 61557, 10000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT513A.jpgUT513A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images145320E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
218E0E425-E9C6-4A3A-96BA-206C816BAAB4FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Tester 12kVUT516B41044403.835945.55005.000012kV Insulation Resistance Tester. IP67, 500V, 1000V, 2500V, 5000V, 10000V & 12000V Range, PC Analysis Software, Data Storage 999, Power Adaptor and Battery - Two Types of Power Mode. High Voltage Alarm Indication, Auto Discharge, PI and DARCAT RATING: CAT IV 600Vhttps://www.uni-trend.co.za/download-catalogue/unitrend-ut516b-series.pdfFA978532-209F-4691-AEF7-D027DCB71861Test Instruments\Electrical Power Testers\Electrical Installation TestersUT516B.jpgUT516B.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images386120E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png 2D431A9AC-C809-4BE0-81B5-344FAF0C1EC3FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FProfessional Digital Earth Tester High Efficiency Earth Ground Insulation Resistance Measure with BlacklightUT5214117278.356069.700019.0000Compact Earth Ground Tester 0-2KO, Manual Range, AC Earth Voltage 200V, Auto Power Off, Low Battery Indication, Data Hold, Data Logging 20, Backlight, Full Icon Display, Double Insulation Protection, Contact Badness Display, Over-Range Display, Simple 2 Wire Testing, Precision 3 Wire Testing, 2000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut520-ut523a-digital-earth-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT521.jpgUT521.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images63290E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
275112753-81BF-4F8C-9D17-3BFC7E1DBB76FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FEarth Resistance Tester Earth Resistance Measurement 0~4000O 0~400V 50Hz/60Hz Count 4000UT5224127839.556197.350019.0000Compact Earth Ground Tester 0-4KO, Manual Range, AC Earth Voltage 400V, Auto Power Off, Low Battery Indication, Data Hold, Data Logging 20, Backlight, Full Icon Display, Double Insulation Protection, Contact Badness Display, Over-Range Display, Simple 2 Wire Testing, Precision 3 Wire Testing, 4000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut520-ut523a-digital-earth-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT522.jpgUT522.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images68170E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
24B663F99-25FF-4C09-977B-D34A1864A57CFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FMultifunction 3 in 1 Electrical Tester 250~1000VUT52641496608070.70003 in 1 Electrical Tester 250~1000V, Insulation Resistance, RCD, Earth Resistance, Voltage Measurement, Low Resistance Continuity, Voltage Measurement, Manual Range, Phase Switch, Low Battery Indication, Automatically Selects DCV or ACV, Red Warning Light, 10000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut526-ut572-multifunction-electrical-meter.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT526.jpgUT526.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images84000E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2877B767C-6164-4AAA-9947-325E816D7478FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Multimeter with Auto-range and True RMSUT5334179126.46381.35007.0000Insulation Resistance Multimeter, Auto Range, True RMS, 1000V AC/DC, 600mA, Resistance 40MO, Capacitance 100µF, Frequency 1MHz, Temperature, Insulation Resistance Test Voltage 100V/250V/500V/1000V, Diode, Auto Power Off, Continuity Buzzer, Low Battery Indication, Data Hold, MAX/MIN, Data Logging 99, Backlight, Full Icon Display, CAT IV 600V, 6000 Count

RANGE: AUTO
TRMS: YES
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
FA978532-209F-4691-AEF7-D027DCB71861Test Instruments\Electrical Power Testers\Electrical Installation TestersUT533.jpgUT533.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images79360E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2A3D58856-519B-4498-A7D2-73BA369D0D71FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FDigital Earth TesterUT57241821495.819000.30003.0000Advanced Earth Resistance Meter, Earth Resistance 40K?, Soil Resistivity 40K?, Disturbance Voltage 50V (DC test or AC test), Disturbance Frequency 40Hz ~ 500Hz, 2/3/4 Wire Test, Earth Resistance Test Frequency, Soil Resistivity Test Distances, Earth Resistance RH and RS Test, Compensating Resistance RK Test, Data Hold, Data Storages 20, LCD Backlight, Autopower Off, Low Battery Indication

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut526-ut572-multifunction-electrical-meter.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT572.jpgUT572.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images186920E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2B3182F0A-DF1E-4C29-AD7E-9B1FE4C7686EFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FDigital RCD (ELCB) TesterUT582 4196751.655510.80004.0000Digital Earth Leakage Circuit Breaker Industrial Tester, RCD Measurement, Data Hold, Phase Switch, Connections Check Function, Auto Ramp Function, Disconnect Buzzer, Over-Range Display, Fused, Mis-Operation Buzzer, Power Off Buzzer, Full Icon Display, 1000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut582-ut585-586-digital-rcd-(elcb)-tester.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT582.jpgUT582.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images58710E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2EBDBE570-657D-4C38-B504-87F43272AD4DFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FMultifunction Installation Tester (Compliance Tester)UT59342218692.1013798.8500196.000001Multi-Function 9 in 1 Loop Tester, Insulation Resistance, Low Resistance Continuity, Line Impedance, Loop Impedance, Loop Impedance Without Tripping, RCD, Phase Sequence Test, RCD Measurement Ramp Slope, AC Voltage, PFC, Auto Power Off, Low Battery Indication, Data Logging, Backlight, Auto Half-Wave Test, RCD Countdown Measurement, RCD Half-Wave Test, Phase Switch (RCD), 10000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V

Includes
• One of each Red Black and green lead
• One of each crocodile clips Red Black and green
• One test lead with 16A plug on one end
• One red test lead that has a switch on the probe to power the meter on
• One carry strap
• One of each test probe Red Black and green
https://www.uni-trend.co.za/download-catalogue/unitrend-ut593-ut595-english-manual.pdfFA978532-209F-4691-AEF7-D027DCB71861Test Instruments\Electrical Power Testers\Electrical Installation TestersUT593.jpgUT593.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images16254E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2F8092545-2922-4256-B94F-2F2A499DE513FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Ground Pile Clamp Earth Resistance TesterUT278C41432409.32.0000UT278C/D Ground Pile Clamp Earth Resistance Tester

  • UT278C/D Earth Clamp Meter, also called Loop Resistance Tester, is used for grounding resistance test. It has multiple functions such as clamping measurement, 3- or 4-wire measurement, voltage/current measurement, data storage/viewing, alarming, auto power off and more. With fast filtering technology employed, interference can be minimized.Designed with 2.4-inch color screen, UT278C/D is characterized by aesthetic appearance, easy to carry, wide range, high resolution, stable performance, strong anti-interference ability. It is mainly used to measure ground resistance of power distribution lines, gas stations, grounding grids, lightning rods, telecommunication, electric power, meteorology, oil fields and others.

  • Models: UT278C, UT278D


Features of UT278C/D Ground Pile Clamp Earth Resistance Tester

  • 2.4-inch color LCD

  • Earth resistance measurement

  • Leakage current measurement

  • Load current measurement

  • Grounding voltage measurement

  • Soil resistivity measurement

  • Alarm function

  • USB data transfer

  • Built-in rechargeable lithium battery

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT278C.jpgUT278C.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images281820E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
29B92EA8B-A9F4-46BE-95E1-8BAFD3EE15FEFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Ground Pile Clamp Earth Resistance TesterUT278D41537003.55UT278C/D Ground Pile Clamp Earth Resistance Tester

  • UT278C/D Earth Clamp Meter, also called Loop Resistance Tester, is used for grounding resistance test. It has multiple functions such as clamping measurement, 3- or 4-wire measurement, voltage/current measurement, data storage/viewing, alarming, auto power off and more. With fast filtering technology employed, interference can be minimized.Designed with 2.4-inch color screen, UT278C/D is characterized by aesthetic appearance, easy to carry, wide range, high resolution, stable performance, strong anti-interference ability. It is mainly used to measure ground resistance of power distribution lines, gas stations, grounding grids, lightning rods, telecommunication, electric power, meteorology, oil fields and others.

  • Models: UT278C, UT278D


Features of UT278C/D Ground Pile Clamp Earth Resistance Tester

  • 2.4-inch color LCD

  • Earth resistance measurement

  • Leakage current measurement

  • Load current measurement

  • Grounding voltage measurement

  • Soil resistivity measurement

  • Alarm function

  • USB data transfer

  • Built-in rechargeable lithium battery

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT278D.jpgUT278D.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images321770E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2D3C84EA4-1468-4E01-ADFA-EDD64626BB9EFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Insulation Resistance TestersUT501C4323248.7514.0000UT60 Series Digital Multimeters

  • UT501C Insulation Resistance Tester, with their new design, large scale integrated circuit and digital circuit, is utilized to measure insulation resistance, alternating voltage and other parameters. The tester has features of complete functions, high accuracy, stable performances, comfortable and reliable operation. The tester is used in maintenance, test and verification for various electrical equipment and is applicable to measure insulation resistance of transformer, motor, cable, switch, electric appliances, etc.


Features of UT501C Insulation Resistance Tester

  • Auto power off

  • Self-lock funciton

  • Overrange indication

  • Backlight function

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT501C.jpgUT501C.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images28250E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2347E49A3-AB84-4AE5-8A67-467B91D279C6FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Insulation Resistance TestersUT502C433UT60 Series Digital Multimeters

  • UT502C Insulation Resistance Tester, with their new design, large scale integrated circuit and digital circuit, is utilized to measure insulation resistance, alternating voltage and other parameters. The tester has features of complete functions, high accuracy, stable performances, comfortable and reliable operation. The tester is used in maintenance, test and verification for various electrical equipment and is applicable to measure insulation resistance of transformer, motor, cable, switch, electric appliances, etc.


Features of UT502C Insulation Resistance Tester

  • Auto power off

  • Self-lock funciton

  • Overrange indication

  • Backlight function

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT502C.jpgUT502C.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images34773998.550E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
21BCBFB13-7ABC-4529-A4B7-885A4795312EFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Intelligent High Voltage 10kV Insulation Resistance Tester Digital MegohmmeterUT515B434Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT515B.jpgUT515B.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png 2DD5C4268-63CF-4E51-8B70-59FE6494F2B1FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Battery Internal Resistance TesterUT677A44017098.262.0000Battery Internal Resistance Tester

  • The battery internal resistance tester is a measuring instrument used to measure the internal resistance, voltage, and temperature of rechargeable batteries such as lead-acid batteries and lithium batteries to judge the health status of the battery.It can also be used as an instrument to measure the ESR parameters of electrolytic capacitors. UT677A uses the AC 4-terminal test method to measure the internal resistance of the battery, which can measure the correct measurement value without being affected by the contact resistance between the test lead, the terminal, and the battery electrode.The whole machine is high-grade and beautiful, with a wide range, high resolution, convenient operation, convenient carrying, accurate, reliable, stable performance, and strong anti-interference ability. It is an indispensable instrument for battery production, battery installation, equipment production, equipment maintenance, and other scenarios.

  • It can also be used as an instrument to measure the ESR parameters of electrolytic capacitors. UT677A uses the AC 4-terminal test method to measure the internal resistance of the battery, which can measure the correct measurement value without being affected by the contact resistance between the test lead, the terminal, and the battery electrode.

  • The whole machine is high-grade and beautiful, with a wide range, high resolution, convenient operation, convenient carrying, accurate, reliable, stable performance, and strong anti-interference ability. It is an indispensable instrument for battery production, battery installation, equipment production, equipment maintenance, and other scenarios.


Battery Internal Resistance Tester

  • Internal resistance test: 0.000mO~3.100 O

  • Voltage test: 0.000V~±71.00V

  • Temperature test: -10.0?~60.0?

  • PC software supported

  • Fast response: =200ms

  • Measurement result judgment function

  • 5000 pieces of data storage & rechargeable lithium battery

  • Bluetooth APP (Android) supported

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT677A.jpgUT677A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images148680E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2213CA5DF-AF3C-4DE8-A2EA-EA33BABAF0B3FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Clamp Earth Resistance TesterUT273 4401715812.0000The UT273 Clamp Earth Resistance Tester is used for earth resistance test. This meter uses an EBTN screen with a dual display function (the resistance & current displayed). It also has functions such as a real-time clock, data storage, data review, alarm, and automatic shutdown.

The tester is characterized by its aesthetic appearance, wide range, high resolution, easy operation, portability, stable performance, and strong ability to resist interference. It is a good tool for electrical engineers.

Features

  • Earth resistance test (0 ~ 600O)

  • Current test (0 ~ 20A

  • Large black screen (32mm)

  • Large jaw size

  • Strong anti-interference

  • Alarm function

  • Data storage (500 sets)
  •  
https://www.uni-trend.co.za/download-catalogue/unitrend-ut273plus-clamp-earth-resistance-tester.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut273plus.jpgut273plus.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/149200E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
24B5F1E4A-CEF8-43B4-84FB-6F84D6F5D5BCFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE252.5kV Insulation Resistance TestersUT512D449UT512D/UT512E is digital high-voltage insulation resistance tester, designed with multiple ranges including 250V, 500V, 1000V, 2500V. It is an ideal measurement meter for electric power, telecommunication, meteorology, machine room, oilfield, electromechanical installation and maintenance, and power supply department of Industry and mining enterprise.


Features

  • Output voltage range: Up to 2.5KV

  • PI/DAR measurement

  • Short circuit current measurement

  • Automatic leakage current display

  • Stepping voltage: 10% of the range

  • High voltage alarm

  • Automatic discharge

  • Data storage: 999 sets

  • PC software analysis: via USB cable

  • Overvoltage category: CAT IV 600V

https://www.uni-trend.co.za/download-catalogue/unitrend-ut512d-ut512e-2.5kv-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut512d.jpgut512d.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/11420131330E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2801DF7FE-41C1-4C24-A05E-56941C722C0DFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Battery TesterUT355045487462.1easy to storage: Simple and compact, easy to use and operate

BANDWIDTH: 150MHZ
CHANNELS: 2 ANALOG
REAL-TIME SAMPLE RATE : 500MSA/S
RISE TIME: =14NS
MEMORY DEPTH: 56MPTS
WAVEFORM CAPTURE RATE: 5000WFMS/S
Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut3550.jpgut3550.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/760540E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
2156E9056-DBF0-4268-93C0-A616D1E60FC0FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE252.5kV Insulation Resistance TestersUT512E457UT512D/UT512E is digital high-voltage insulation resistance tester, designed with multiple ranges including 250V, 500V, 1000V, 2500V. It is an ideal measurement meter for electric power, telecommunication, meteorology, machine room, oilfield, electromechanical installation and maintenance, and power supply department of Industry and mining enterprise.


Features

  • Output voltage range: Up to 2.5KV

  • PI/DAR measurement

  • Short circuit current measurement

  • Automatic leakage current display

  • Stepping voltage: 10% of the range

  • High voltage alarm

  • Automatic discharge

  • Data storage: 999 sets

  • PC software analysis: via USB cable

  • Overvoltage category: CAT IV 600V

 
https://www.uni-trend.co.za/download-catalogue/unitrend-ut512d-ut512e-2.5kv-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut512d.jpgut512d.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/1357415610.10E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
23EC41774-F50E-461E-A0A7-FF9CC024D049FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE255kV Insulation Resistance TestersUT513B458UT513B/UT513C are digital high-voltage insulation resistance testers with high-voltage output ranges of 250V, 500V, 1000V, 2500V, and 5000V. They are commonly used and essential instruments for power, telecommunications, meteorology, computer rooms, oil fields, electromechanical installation and maintenance, and power supply departments of industrial and mining enterprises.


  • Output voltage: Up to 5kV
  •  
  • PI & DAR measurement
  •  
  • Automatic leakage current display
  •  
  • Stepping voltage: 10% of the range
  •  
  • Comparison function
  •  
  • Timer measurement
  •  
  • Data storage: 999 sets
  •  
  • PC software analysis: via USB cable
  •  
  • Automatic discharge
  •  
  • High voltage output alarm function
  •  
  • Rechargeable lithium battery 14.8V, 5200mAh
  •  
  • Overvoltage category: CAT IV 600V
  •  
https://www.uni-trend.co.za/download-catalogue/unitrend-ut513b-utT513c-5kv-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut513b.jpgut513b.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/1907321933.950E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png
27A359A2B-3D51-434B-AAEF-3A5E8C117DBCFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE255kV Insulation Resistance TestersUT513C459UT513B/UT513C are digital high-voltage insulation resistance testers with high-voltage output ranges of 250V, 500V, 1000V, 2500V, and 5000V. They are commonly used and essential instruments for power, telecommunications, meteorology, computer rooms, oil fields, electromechanical installation and maintenance, and power supply departments of industrial and mining enterprises.


  • Output voltage: Up to 5kV
  •  
  • PI & DAR measurement
  •  
  • Automatic leakage current display
  •  
  • Stepping voltage: 10% of the range
  •  
  • Comparison function
  •  
  • Timer measurement
  •  
  • Data storage: 999 sets
  •  
  • PC software analysis: via USB cable
  •  
  • Automatic discharge
  •  
  • High voltage output alarm function
  •  
  • Rechargeable lithium battery 14.8V, 5200mAh
  •  
  • Overvoltage category: CAT IV 600V
  •  
https://www.uni-trend.co.za/download-catalogue/unitrend-ut513b-utT513c-5kv-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut513b.jpgut513b.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/23940275310E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

Electrical Installation Testers

2AB30F1D6-EB94-4B22-A350-FAB1796F07FEFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847F1000V Compact Insulation Resistance TesterUT501A413974.402298.8500157.000001Compact Insulation Resistance Tester 100V/250V/500V/1000V, ACV 750V, Auto Range, Low Battery Indication, Backlight, Alarm Light Display, Alarm Buzzer, High Voltage Indication, Over Load Indication, Auto Discharge, Test Voltage Vice Display, 10MO Internal Resistance Test, CAT II 1000V CAT III 600V, 2000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT II 1000V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT501A.jpgUT501A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images3456E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT501A 1000V Compact Insulation Resistance Tester

2A846F125-0B5F-4D2D-B941-449D1E08F4CAFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847F1000V Compact Insulation Resistance Tester Ground MeterUT501B424597.73788.1000110.0000Compact Insulation Resistance Tester 100V/250V/500V/1000V, ACV 600V, Auto Range, Low Resistance 0.01?-200?, DAR, PI, Low Battery Indication, Backlight, Alarm Light Display, Alarm Buzzer, High Voltage Indication, Over Load Indication, Auto Discharge, Test Voltage Vice Display, 10MO Internal Resistance Test, CAT II 1000V CAT III 600V, 2000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT501B.jpgUT501B.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images39980E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT501B 1000V Compact Insulation Resistance Tester Ground Meter

23D4D2B16-F97A-4315-A097-4E859B9F8252FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Tester insulation resistance, LCD (2000) with a backlitUT502A436880.455631.5500Compact Insulation Resistance Tester 500V/1000V/2500V, DCV & ACV, Auto Range, Low Battery Indication, Backlight, Alarm Light Display, Alarm Buzzer, High Voltage Indication, Over-Load Indication, Auto Discharge,Test Voltage Vice Display, PI/DAR, CAT II 1000V CAT III 600V, 2000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT502A.jpgUT502A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images59830E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT502A Insulation Resistance Tester insulation resistance, LCD (2000) with a backlit

2E80B1134-4706-41CF-B010-F7D3161BEB0EFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FHandheld Digital Insulation Resistance Tester 6000-count True RMSUT505A448820.57128.85006.0000Handheld Insulation Resistance Tester, 50V/100V/250V/500V/1000V Test Voltage. 0.1M?-20G?. Short Circuit Current <2mA, Low Resistance, AC/DC Voltage 600V, Auto Range, True RMS, Step Voltage, DAR, PI, Timer, High Voltage Indication, Analogue Bar Graph, Auto Power Off, Continuity Buzzer, Data Hold, Data Storage 99, Comparison, Backlight, CAT IV 600V, 6000 Count

RANGE: AUTO
TRMS: YES
SPECIFICATION: CE/RoHS
CAT RATING: CAT IV 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT505A.jpgUT505A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images76700E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT505A Handheld Digital Insulation Resistance Tester 6000-count True RMS

2C27C5FE5-5BE0-40E3-BAF1-3BA79951FB28FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Tester with Auto Range True RMS Data that Hold Freq/cap Fuse and Self TestUT505B4512185.48407.650013.0000Handheld Insulation Resistance Tester, 50V/100V/250V/500V/1000V Test Voltage. 0.1M?-200G?. Short Circuit Current <2mA, Low Resistance, AC/DC Voltage 600V, Leakage Current 10~2000µA, General Resistance 0.0kO~1000kO, Frequency 450Hz, Capacitance 100pF~10µF, Auto Range, True RMS, Step Voltage, DAR, PI, Timer, High Voltage Indication, Analogue Bar Graph, Auto Power Off, Continuity Buzzer, Data Hold, Data Storage 99, Comparison, Backlight, CAT IV 600V, 6000 Count

RANGE: AUTO
TRMS: YES
SPECIFICATION: CE/RoHS
CAT RATING: CAT IV 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT505B.jpgUT505B.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images105960E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT505B Insulation Resistance Tester with Auto Range True RMS Data that Hold Freq/cap Fuse and Self Test

23EA514C8-ED59-4C77-98C3-9DEAD4293666FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance TesterUT511466229.554974.90005.0000Insulation Resistance Tester 100V/250V/500V/1000V, DCV 1000V, ACV 750V, Low Resistance 999.9O, Auto Range, Auto Power Off, Low Battery Indication, Data Logging 18, Comparison, Polarisation Index (PI), Dielectric Absorption (DAR), Backlight, Analogue Bar Graph, Over Range Warning, High Voltage Indication, Timer -30 Minutes, 10000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT511.jpgUT511.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images54170E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT511 Insulation Resistance Tester

25E8D52F5-3D5B-44FF-A44C-E4F32A771BDAFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Tester 500V/1000V/1500V/2500V 0%~20% High-voltage PI DAR Tester USB PC SoftwareUT512478688.257177.15009.0000Insulation Resistance Tester 500V/1000V/1500V/2500V, DCV 600V, ACV 600V, Auto Range, Auto Power Off, Low Battery Indication, Data Logging 18, Comparison, Polarisation Index (PI), Dielectric Absorption (DAR), USB, Backlight, Analogue Bar Graph, Over Range Warning, High Voltage Indication, Timer -15 Minutes, 10000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT512.jpgUT512.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images75550E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT512 Insulation Resistance Tester 500V/1000V/1500V/2500V 0%~20% High-voltage PI DAR Tester USB PC Software

26EAA9244-C0F7-49FA-A87B-4C93FAA21916FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FDigital Insulation Resistance Tester, 500V/1000V/2500V/5000V, Auto Range, Display Count: 9999UT513A4916711.810683.850010.0000Insulation Resistance Tester 500V/1000V/2500V/5000V, DCV 600V, ACV 600V, Auto Range, Secondary Display, Auto Power Off, Low Battery Indication, Data Logging 18, Comparison, Polarisation Index (PI), Dielectric Absorption (DAR), USB, Backlight, Analogue Bar Graph, Over Range Warning, High Voltage Indication, Timer -15 Minutes, Meets IEC 61557, 10000 Count

RANGE: AUTO
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut505-handheld-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT513A.jpgUT513A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images145320E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT513A Digital Insulation Resistance Tester, 500V/1000V/2500V/5000V, Auto Range, Display Count: 9999

218E0E425-E9C6-4A3A-96BA-206C816BAAB4FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Tester 12kVUT516B41044403.835945.55005.000012kV Insulation Resistance Tester. IP67, 500V, 1000V, 2500V, 5000V, 10000V & 12000V Range, PC Analysis Software, Data Storage 999, Power Adaptor and Battery - Two Types of Power Mode. High Voltage Alarm Indication, Auto Discharge, PI and DARCAT RATING: CAT IV 600Vhttps://www.uni-trend.co.za/download-catalogue/unitrend-ut516b-series.pdfFA978532-209F-4691-AEF7-D027DCB71861Test Instruments\Electrical Power Testers\Electrical Installation TestersUT516B.jpgUT516B.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images386120E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT516B Insulation Resistance Tester 12kV

2D431A9AC-C809-4BE0-81B5-344FAF0C1EC3FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FProfessional Digital Earth Tester High Efficiency Earth Ground Insulation Resistance Measure with BlacklightUT5214117278.356069.700019.0000Compact Earth Ground Tester 0-2KO, Manual Range, AC Earth Voltage 200V, Auto Power Off, Low Battery Indication, Data Hold, Data Logging 20, Backlight, Full Icon Display, Double Insulation Protection, Contact Badness Display, Over-Range Display, Simple 2 Wire Testing, Precision 3 Wire Testing, 2000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut520-ut523a-digital-earth-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT521.jpgUT521.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images63290E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT521 Professional Digital Earth Tester High Efficiency Earth Ground Insulation Resistance Measure with Blacklight

275112753-81BF-4F8C-9D17-3BFC7E1DBB76FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FEarth Resistance Tester Earth Resistance Measurement 0~4000O 0~400V 50Hz/60Hz Count 4000UT5224127839.556197.350019.0000Compact Earth Ground Tester 0-4KO, Manual Range, AC Earth Voltage 400V, Auto Power Off, Low Battery Indication, Data Hold, Data Logging 20, Backlight, Full Icon Display, Double Insulation Protection, Contact Badness Display, Over-Range Display, Simple 2 Wire Testing, Precision 3 Wire Testing, 4000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut520-ut523a-digital-earth-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT522.jpgUT522.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images68170E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT522 Earth Resistance Tester Earth Resistance Measurement 0~4000O 0~400V 50Hz/60Hz Count 4000

24B663F99-25FF-4C09-977B-D34A1864A57CFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FMultifunction 3 in 1 Electrical Tester 250~1000VUT52641496608070.70003 in 1 Electrical Tester 250~1000V, Insulation Resistance, RCD, Earth Resistance, Voltage Measurement, Low Resistance Continuity, Voltage Measurement, Manual Range, Phase Switch, Low Battery Indication, Automatically Selects DCV or ACV, Red Warning Light, 10000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut526-ut572-multifunction-electrical-meter.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT526.jpgUT526.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images84000E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT526 Multifunction 3 in 1 Electrical Tester 250~1000V

2F8092545-2922-4256-B94F-2F2A499DE513FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Ground Pile Clamp Earth Resistance TesterUT278C41432409.32.0000UT278C/D Ground Pile Clamp Earth Resistance Tester

  • UT278C/D Earth Clamp Meter, also called Loop Resistance Tester, is used for grounding resistance test. It has multiple functions such as clamping measurement, 3- or 4-wire measurement, voltage/current measurement, data storage/viewing, alarming, auto power off and more. With fast filtering technology employed, interference can be minimized.Designed with 2.4-inch color screen, UT278C/D is characterized by aesthetic appearance, easy to carry, wide range, high resolution, stable performance, strong anti-interference ability. It is mainly used to measure ground resistance of power distribution lines, gas stations, grounding grids, lightning rods, telecommunication, electric power, meteorology, oil fields and others.

  • Models: UT278C, UT278D


Features of UT278C/D Ground Pile Clamp Earth Resistance Tester

  • 2.4-inch color LCD

  • Earth resistance measurement

  • Leakage current measurement

  • Load current measurement

  • Grounding voltage measurement

  • Soil resistivity measurement

  • Alarm function

  • USB data transfer

  • Built-in rechargeable lithium battery

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT278C.jpgUT278C.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images281820E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT278C Ground Pile Clamp Earth Resistance Tester

29B92EA8B-A9F4-46BE-95E1-8BAFD3EE15FEFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Ground Pile Clamp Earth Resistance TesterUT278D41537003.55UT278C/D Ground Pile Clamp Earth Resistance Tester

  • UT278C/D Earth Clamp Meter, also called Loop Resistance Tester, is used for grounding resistance test. It has multiple functions such as clamping measurement, 3- or 4-wire measurement, voltage/current measurement, data storage/viewing, alarming, auto power off and more. With fast filtering technology employed, interference can be minimized.Designed with 2.4-inch color screen, UT278C/D is characterized by aesthetic appearance, easy to carry, wide range, high resolution, stable performance, strong anti-interference ability. It is mainly used to measure ground resistance of power distribution lines, gas stations, grounding grids, lightning rods, telecommunication, electric power, meteorology, oil fields and others.

  • Models: UT278C, UT278D


Features of UT278C/D Ground Pile Clamp Earth Resistance Tester

  • 2.4-inch color LCD

  • Earth resistance measurement

  • Leakage current measurement

  • Load current measurement

  • Grounding voltage measurement

  • Soil resistivity measurement

  • Alarm function

  • USB data transfer

  • Built-in rechargeable lithium battery

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT278D.jpgUT278D.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images321770E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT278D Ground Pile Clamp Earth Resistance Tester

2877B767C-6164-4AAA-9947-325E816D7478FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FInsulation Resistance Multimeter with Auto-range and True RMSUT5334179126.46381.35007.0000Insulation Resistance Multimeter, Auto Range, True RMS, 1000V AC/DC, 600mA, Resistance 40MO, Capacitance 100µF, Frequency 1MHz, Temperature, Insulation Resistance Test Voltage 100V/250V/500V/1000V, Diode, Auto Power Off, Continuity Buzzer, Low Battery Indication, Data Hold, MAX/MIN, Data Logging 99, Backlight, Full Icon Display, CAT IV 600V, 6000 Count

RANGE: AUTO
TRMS: YES
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
FA978532-209F-4691-AEF7-D027DCB71861Test Instruments\Electrical Power Testers\Electrical Installation TestersUT533.jpgUT533.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images79360E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT533 Insulation Resistance Multimeter with Auto-range and True RMS

2A3D58856-519B-4498-A7D2-73BA369D0D71FA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FDigital Earth TesterUT57241821495.819000.30003.0000Advanced Earth Resistance Meter, Earth Resistance 40K?, Soil Resistivity 40K?, Disturbance Voltage 50V (DC test or AC test), Disturbance Frequency 40Hz ~ 500Hz, 2/3/4 Wire Test, Earth Resistance Test Frequency, Soil Resistivity Test Distances, Earth Resistance RH and RS Test, Compensating Resistance RK Test, Data Hold, Data Storages 20, LCD Backlight, Autopower Off, Low Battery Indication

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut526-ut572-multifunction-electrical-meter.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT572.jpgUT572.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images186920E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT572 Digital Earth Tester

2B3182F0A-DF1E-4C29-AD7E-9B1FE4C7686EFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FDigital RCD (ELCB) TesterUT582 4196751.655510.80004.0000Digital Earth Leakage Circuit Breaker Industrial Tester, RCD Measurement, Data Hold, Phase Switch, Connections Check Function, Auto Ramp Function, Disconnect Buzzer, Over-Range Display, Fused, Mis-Operation Buzzer, Power Off Buzzer, Full Icon Display, 1000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V
https://www.uni-trend.co.za/download-catalogue/unitrend-ut582-ut585-586-digital-rcd-(elcb)-tester.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersFA978532-209F-4691-AEF7-D027DCB71861UT582.jpgUT582.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images58710E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT582 Digital RCD (ELCB) Tester

2EBDBE570-657D-4C38-B504-87F43272AD4DFA978532-209F-4691-AEF7-D027DCB71861A0403786-F930-428C-AC2A-4F709F7D847FMultifunction Installation Tester (Compliance Tester)UT59342218692.1013798.8500196.000001Multi-Function 9 in 1 Loop Tester, Insulation Resistance, Low Resistance Continuity, Line Impedance, Loop Impedance, Loop Impedance Without Tripping, RCD, Phase Sequence Test, RCD Measurement Ramp Slope, AC Voltage, PFC, Auto Power Off, Low Battery Indication, Data Logging, Backlight, Auto Half-Wave Test, RCD Countdown Measurement, RCD Half-Wave Test, Phase Switch (RCD), 10000 Count

RANGE: MANUAL
SPECIFICATION: CE/RoHS
CAT RATING: CAT III 600V

Includes
• One of each Red Black and green lead
• One of each crocodile clips Red Black and green
• One test lead with 16A plug on one end
• One red test lead that has a switch on the probe to power the meter on
• One carry strap
• One of each test probe Red Black and green
https://www.uni-trend.co.za/download-catalogue/unitrend-ut593-ut595-english-manual.pdfFA978532-209F-4691-AEF7-D027DCB71861Test Instruments\Electrical Power Testers\Electrical Installation TestersUT593.jpgUT593.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images16254E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT593 Multifunction Installation Tester (Compliance Tester)

2D3C84EA4-1468-4E01-ADFA-EDD64626BB9EFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Insulation Resistance TestersUT501C4323248.7514.0000UT60 Series Digital Multimeters

  • UT501C Insulation Resistance Tester, with their new design, large scale integrated circuit and digital circuit, is utilized to measure insulation resistance, alternating voltage and other parameters. The tester has features of complete functions, high accuracy, stable performances, comfortable and reliable operation. The tester is used in maintenance, test and verification for various electrical equipment and is applicable to measure insulation resistance of transformer, motor, cable, switch, electric appliances, etc.


Features of UT501C Insulation Resistance Tester

  • Auto power off

  • Self-lock funciton

  • Overrange indication

  • Backlight function

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT501C.jpgUT501C.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images28250E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT501C Insulation Resistance Testers

2347E49A3-AB84-4AE5-8A67-467B91D279C6FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Insulation Resistance TestersUT502C433UT60 Series Digital Multimeters

  • UT502C Insulation Resistance Tester, with their new design, large scale integrated circuit and digital circuit, is utilized to measure insulation resistance, alternating voltage and other parameters. The tester has features of complete functions, high accuracy, stable performances, comfortable and reliable operation. The tester is used in maintenance, test and verification for various electrical equipment and is applicable to measure insulation resistance of transformer, motor, cable, switch, electric appliances, etc.


Features of UT502C Insulation Resistance Tester

  • Auto power off

  • Self-lock funciton

  • Overrange indication

  • Backlight function

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT502C.jpgUT502C.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images34773998.550E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT502C Insulation Resistance Testers

21BCBFB13-7ABC-4529-A4B7-885A4795312EFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Intelligent High Voltage 10kV Insulation Resistance Tester Digital MegohmmeterUT515B434Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT515B.jpgUT515B.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT515B Intelligent High Voltage 10kV Insulation Resistance Tester Digital Megohmmeter

2DD5C4268-63CF-4E51-8B70-59FE6494F2B1FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Battery Internal Resistance TesterUT677A44017098.262.0000Battery Internal Resistance Tester

  • The battery internal resistance tester is a measuring instrument used to measure the internal resistance, voltage, and temperature of rechargeable batteries such as lead-acid batteries and lithium batteries to judge the health status of the battery.It can also be used as an instrument to measure the ESR parameters of electrolytic capacitors. UT677A uses the AC 4-terminal test method to measure the internal resistance of the battery, which can measure the correct measurement value without being affected by the contact resistance between the test lead, the terminal, and the battery electrode.The whole machine is high-grade and beautiful, with a wide range, high resolution, convenient operation, convenient carrying, accurate, reliable, stable performance, and strong anti-interference ability. It is an indispensable instrument for battery production, battery installation, equipment production, equipment maintenance, and other scenarios.

  • It can also be used as an instrument to measure the ESR parameters of electrolytic capacitors. UT677A uses the AC 4-terminal test method to measure the internal resistance of the battery, which can measure the correct measurement value without being affected by the contact resistance between the test lead, the terminal, and the battery electrode.

  • The whole machine is high-grade and beautiful, with a wide range, high resolution, convenient operation, convenient carrying, accurate, reliable, stable performance, and strong anti-interference ability. It is an indispensable instrument for battery production, battery installation, equipment production, equipment maintenance, and other scenarios.


Battery Internal Resistance Tester

  • Internal resistance test: 0.000mO~3.100 O

  • Voltage test: 0.000V~±71.00V

  • Temperature test: -10.0?~60.0?

  • PC software supported

  • Fast response: =200ms

  • Measurement result judgment function

  • 5000 pieces of data storage & rechargeable lithium battery

  • Bluetooth APP (Android) supported

Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25UT677A.jpgUT677A.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images148680E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT677A Battery Internal Resistance Tester

2213CA5DF-AF3C-4DE8-A2EA-EA33BABAF0B3FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Clamp Earth Resistance TesterUT273 4401715812.0000The UT273 Clamp Earth Resistance Tester is used for earth resistance test. This meter uses an EBTN screen with a dual display function (the resistance & current displayed). It also has functions such as a real-time clock, data storage, data review, alarm, and automatic shutdown.

The tester is characterized by its aesthetic appearance, wide range, high resolution, easy operation, portability, stable performance, and strong ability to resist interference. It is a good tool for electrical engineers.

Features

  • Earth resistance test (0 ~ 600O)

  • Current test (0 ~ 20A

  • Large black screen (32mm)

  • Large jaw size

  • Strong anti-interference

  • Alarm function

  • Data storage (500 sets)
  •  
https://www.uni-trend.co.za/download-catalogue/unitrend-ut273plus-clamp-earth-resistance-tester.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut273plus.jpgut273plus.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/149200E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT273 Clamp Earth Resistance Tester

24B5F1E4A-CEF8-43B4-84FB-6F84D6F5D5BCFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE252.5kV Insulation Resistance TestersUT512D449UT512D/UT512E is digital high-voltage insulation resistance tester, designed with multiple ranges including 250V, 500V, 1000V, 2500V. It is an ideal measurement meter for electric power, telecommunication, meteorology, machine room, oilfield, electromechanical installation and maintenance, and power supply department of Industry and mining enterprise.


Features

  • Output voltage range: Up to 2.5KV

  • PI/DAR measurement

  • Short circuit current measurement

  • Automatic leakage current display

  • Stepping voltage: 10% of the range

  • High voltage alarm

  • Automatic discharge

  • Data storage: 999 sets

  • PC software analysis: via USB cable

  • Overvoltage category: CAT IV 600V

https://www.uni-trend.co.za/download-catalogue/unitrend-ut512d-ut512e-2.5kv-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut512d.jpgut512d.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/11420131330E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT512D 2.5kV Insulation Resistance Testers

2801DF7FE-41C1-4C24-A05E-56941C722C0DFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE25Battery TesterUT355045487462.1easy to storage: Simple and compact, easy to use and operate

BANDWIDTH: 150MHZ
CHANNELS: 2 ANALOG
REAL-TIME SAMPLE RATE : 500MSA/S
RISE TIME: =14NS
MEMORY DEPTH: 56MPTS
WAVEFORM CAPTURE RATE: 5000WFMS/S
Test Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut3550.jpgut3550.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/760540E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT3550 Battery Tester

2156E9056-DBF0-4268-93C0-A616D1E60FC0FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE252.5kV Insulation Resistance TestersUT512E457UT512D/UT512E is digital high-voltage insulation resistance tester, designed with multiple ranges including 250V, 500V, 1000V, 2500V. It is an ideal measurement meter for electric power, telecommunication, meteorology, machine room, oilfield, electromechanical installation and maintenance, and power supply department of Industry and mining enterprise.


Features

  • Output voltage range: Up to 2.5KV

  • PI/DAR measurement

  • Short circuit current measurement

  • Automatic leakage current display

  • Stepping voltage: 10% of the range

  • High voltage alarm

  • Automatic discharge

  • Data storage: 999 sets

  • PC software analysis: via USB cable

  • Overvoltage category: CAT IV 600V

 
https://www.uni-trend.co.za/download-catalogue/unitrend-ut512d-ut512e-2.5kv-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut512d.jpgut512d.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/1357415610.10E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT512E 2.5kV Insulation Resistance Testers

23EC41774-F50E-461E-A0A7-FF9CC024D049FA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE255kV Insulation Resistance TestersUT513B458UT513B/UT513C are digital high-voltage insulation resistance testers with high-voltage output ranges of 250V, 500V, 1000V, 2500V, and 5000V. They are commonly used and essential instruments for power, telecommunications, meteorology, computer rooms, oil fields, electromechanical installation and maintenance, and power supply departments of industrial and mining enterprises.


  • Output voltage: Up to 5kV
  •  
  • PI & DAR measurement
  •  
  • Automatic leakage current display
  •  
  • Stepping voltage: 10% of the range
  •  
  • Comparison function
  •  
  • Timer measurement
  •  
  • Data storage: 999 sets
  •  
  • PC software analysis: via USB cable
  •  
  • Automatic discharge
  •  
  • High voltage output alarm function
  •  
  • Rechargeable lithium battery 14.8V, 5200mAh
  •  
  • Overvoltage category: CAT IV 600V
  •  
https://www.uni-trend.co.za/download-catalogue/unitrend-ut513b-utT513c-5kv-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut513b.jpgut513b.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/1907321933.950E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT513B 5kV Insulation Resistance Testers

27A359A2B-3D51-434B-AAEF-3A5E8C117DBCFA978532-209F-4691-AEF7-D027DCB71861E2A3A544-99A9-4BE4-80E1-33AEB4F7CE255kV Insulation Resistance TestersUT513C459UT513B/UT513C are digital high-voltage insulation resistance testers with high-voltage output ranges of 250V, 500V, 1000V, 2500V, and 5000V. They are commonly used and essential instruments for power, telecommunications, meteorology, computer rooms, oil fields, electromechanical installation and maintenance, and power supply departments of industrial and mining enterprises.


  • Output voltage: Up to 5kV
  •  
  • PI & DAR measurement
  •  
  • Automatic leakage current display
  •  
  • Stepping voltage: 10% of the range
  •  
  • Comparison function
  •  
  • Timer measurement
  •  
  • Data storage: 999 sets
  •  
  • PC software analysis: via USB cable
  •  
  • Automatic discharge
  •  
  • High voltage output alarm function
  •  
  • Rechargeable lithium battery 14.8V, 5200mAh
  •  
  • Overvoltage category: CAT IV 600V
  •  
https://www.uni-trend.co.za/download-catalogue/unitrend-ut513b-utT513c-5kv-insulation-resistance-testers.pdfTest Instruments\Electrical Power Testers\Electrical Installation TestersE2A3A544-99A9-4BE4-80E1-33AEB4F7CE25ut513b.jpgut513b.jpg(PATHUPLOAD)\__upload\ThreeD\Catalogue\images/23940275310E:\wwwRoot\ecat_upload\__upload\ThreeD\Catalogue\images\logo\brand-unit.png

UT513C 5kV Insulation Resistance Testers

Feedback

We welcome your feedback

Please rate your satisfaction with our website:

1
2
3
4
5
6
7
8
9
10
Not at all satisfiedExtremely satisfied